A stairway within the exit access portion of the means of egress system.
Ibc 2015 roof access requirements.
International building code 2015 ibc 2015 chapter 1 scope and administration chapter 2 definitions chapter 3 use and occupancy classification chapter 4 special.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Imc 2015 section 306 5 equipment and appliances on roofs or elevation structures says access shall be provided.
1 revisor 1305 1209 1305 1209section1209 accesstounoccupiedspaces.
Codenotes worker safety on roofs and elevated structures based on the 2015 international mechanical code figure 1 access and service space figure 2 landing requirements.
Such access shall not require climbing over obstructions greater than 30 inches.
In buildings of 4 or more stories above grade plane ibc requires certain buildings to provide access to the roof.
Where a stairway is provided to a roof access to the roof shall be provided through a penthouse complying with section 1510 2 of the california building code.
In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5 m 2 in area and having a minimum dimension of 2 feet 610 mm.
Ibc 2015 section 1103 2 9 equipment spaces exempts the access from chapter 11 requirements.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Exit access travel distance.
The side railing shall extend above the parapet or roof edge not less than 30 inches 762 mm.
2015 international building code errata portions of text and tables not shown are unaffected by the errata third printing updated april 15 2020 chapter 2.
Where access involves climbing over parapet walls the height shall be measured to the top of the parapet wall.
In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5 m in area and having a minimum dimension of 24 inches 610 mm.
This article focuses on the more substantial revisions that are relevant to the fire protection community.
Section 1507 requirements for roof coverings.
By beth tubbs p e fsfpe the 2015 edition of the international building code 1 ibc will be published in the near future along with the complete family of coordinated i codes.
2015 ibc 1011 12 2 roof access states.