The following product options will allow you to achieve an intake nfva of 528 square inches.
Ibc attic vent requirment.
No interior class i vapor retarders are installed on the ceiling side attic floor of the unvented attic assembly or on the ceiling side of the unvented enclosed roof framing assembly.
Designers may view unvented attic i e.
Attic space enclosed rafter or joist space above normally occupied and conditioned interior space assemblies as an economical arrangement of roofing and insulation materials.
Tips for assessing your needs.
Ventsure inflow intake vent.
See chapter 10 means of egress particularly 1011 12 stairway to roof 1011 12 2 roof access and 1011 16 ladders.
However insulation placement in roof assemblies requires careful review to achieve acceptable hygrothermal performance levels and limit the.
Ibc 1203 2 requires 1 150 th of the attic area to be ventilated but there is an exception that is commonly used instead.
Chapter 9 roof assemblies.
2018 international building code.
On the upcodes website.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Insulation requirements for roofs are therefore spread across ibc chapters 12 13 and 15.
Allows cool dry air to enter the attic.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Exception 1 allows you to only ventilate 1 300 th of the attic area if 50 to 80 of the ventilation occurs at least 3 above eave or cornice vents.
Theinternational building code 2012 edition ibc 2012 requires enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof framing to have cross ventilation for each separate space.
The following are the requirements taken directly from the irc.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
The ventilation amount and opening size requirements can be found in section 806 roof ventilation of chapter 8 roof ceiling construction.
The majority of the requirements related to attic ventilation have not changed much from the previous editions.
Choose one of the following products to meet the recommended intake nfva of 528 square inches.
Where wood shingles or shakes are used a minimum 1 4 inch 6 4 mm vented airspace separates the shingles or shakes and the roofing underlayment above the structural sheathing.
The net free vent area nfva shall not be less than 1 150 of the area of the space being vented.