These hatches are typically located over a ladder or staircase that provides access to the roof.
Imc roof access hatch minimum size.
According to california mechanical code section 303 9 roof access panels must have a clearance of at least 30 inches allowing personnel to safely access any rooftop equipment or enclosure.
Ladders shall have a toe spacing not less than 6 inches deep.
2015 ibc 1011 12 2 roof access states.
In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5 m in area and having a minimum dimension of 24 inches 610 mm.
In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5m2 in area and having a minimum dimension of 2 feet 610 mm.
As per section 1009 12 1 roof access exception.
These hatches are generally larger in order to accommodate the installation or removal of equipment or machinery into a building.
Ladders shall have rung spacing not to exceed 14 inches on center.
Such access shall not require climbing over obstructions greater than 30 inches 762 mm in height or walking on roofs having a slope greater than 4 units vertical in 12 units horizontal 33 percent slope.
The side railing shall extend above the parapet or roof edge not less than 30 inches.
Guards shall be provided where various components that require service and roof hatch openings are located within 10 feet 3048 mm of a roof edge or open side of a walking.
Also according to clark county building inspection guidelines access doors should allow a lip of one and a half inches at the bottom of each duct and one inch on the top and side.
Distance of 2 feet does this meet the roof hatch has to be 16 square feet or a trap door needs to be that min.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Installation 48 2015 imc study companion code text.
A permanent approved means of access such as a fixed permanent ladder is not required for group r 3 occupancies.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Guards shall be provided where various components that require service and roof hatch openings are located within 10 feet 3048 mm of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches 762 mm above the floor roof or grade below.
Permanent ladders installed to provide the required access shall comply with the following minimum design criteria.
In buildings of 4 or more stories above grade plane ibc requires certain buildings to provide access to the roof.