In it we have a 200 amp main breaker.
How to size breaker for solar panels.
Here s a chart for wire sizes looking for 60a 4 is safe 6 is possibly allowable if you have the high temp insulation.
A 60 amp fuse or breaker should be used in this case to protect this wire set.
Size of dc breaker for solar panel actually if i miss my guess here and remember it correctly it is imp x 1 25 x 1 25 and rounded up to the nearest commercial value.
This also aligns with the maximum capacity of the charge controller selected.
Busbar rating a x 1 2 main breaker rating a max pv a let s start with an example.
The general rule of thumb is that circuit breaker size should be 125 of the ampacity of cable and wire or the circuit which has to be protected by the cb.
We have a 200 amp bus rating for our service panel.
You use a breaker with a voltage rating for the type of current dc and amps to protect the wire gauge.
An 8 awg use 2 wire set minimum from the combiner box to the charge controller in our example will suffice since it can handle 55 amps.
1 choose the right circuit breaker for solar the power coming from your grid tie solar system is 240vac so you will.
If the utility requires a disconnect between the inverter and main panel board this could be a 60a fused or non fused disconnect dependig on their requirements.
2 make sure current rating is good current rating inverter nominal output current x 1 25.
Then go up the next common.
3 follow the code there is a code rule nec 690 64 b.
First between the charge controller and battery bank second between the charge controller and solar panels and third would be between the battery bank and inverter to determine the fuse size needed between the charge controller and battery bank you simply match the amperage rating on the charge controller.
From there you d land your inverter s output into a 50a breaker and your done.
Do you have access to a 60a dc breaker not an automotive or car stereo breaker.
There are three different locations that we recommend installing fuses or breakers.
Take 35 5a x 1 25 44 4a round up to the next standard trade size which will be 50a.